What survives a restart
The Control UI retains accepted text and attachments in its outbox until the
Gateway confirms transcript consumption. After reconnecting, it checks the saved
receipt before resubmitting an interrupted input through normal authentication
and session admission. The old queue and execution authority are never reused.
This preserves each browser outbox’s order without submitting already-consumed
messages again. Different browsers can reconnect in a different order.
Accepted Control UI input is committed to its admitted source session before ACP
execution or question consumption. If the conversation routes to a bound ACP
session, the source keeps the original request and the bound session owns the ACP
transcript and reply. An output-persistence failure does not make consumed input
eligible for automatic resubmission.
If the browser no longer has the matching outbox payload, the saved interrupted
input remains available for explicit resend. Cancelled input is not replayed.
Inputs accepted by older versions without resumable custody also require explicit resend.
An uncertain submission stays unconfirmed until its outcome can be reconciled
or the user chooses to retry it. Recovery of a turn already in the transcript
does not depend on the browser returning.
When an update replaces the bundled Control UI, an open tab reloads after the
Gateway reports the new build. Automatic recovery for that reported build and
manual reloads share a bounded document-readiness check, so a transient failed
probe does not immediately strand the tab. Generic lazy-chunk failures make one
automatic probe and leave further recovery to the visible retry action. The
browser still limits automatic navigation to one reload per target build. If the
Gateway remains unavailable, use the visible reload action once it is reachable.
Downgrading to
v2026.9.2 preserves newer accepted-input records, but that version
rejects same-ID retries against retained newer receipts before execution. This
includes queued or interrupted inputs and consumed collected-input receipts.
Consumed receipts remain excluded from pending counts. Individually consumed
inputs have already left the pending-input store and retain normal transcript
idempotency. Upgrading again restores matching unconsumed-input recovery through
fresh authentication and admission, provided the session and accepted input have
not been changed or removed. Already-consumed input remains consumed. Do not
delete receipts or change message IDs merely to bypass a downgrade conflict.
Native Codex recovery reconstructs saved document contents under the current
attachment policy and context limits. The Codex plugin owns that native input
path: update its artifact alongside the Gateway. An intentionally pinned older
plugin does not acquire the fix from a core-only update.
A detached harness completion that has entered a parent turn with an outbound
channel route can retain an exact task, terminal outcome, and requester-session claim. After a crash, main-session recovery
continues that admitted turn without starting the child again. The original
completion identity remains distinct from the recovery run. A retained final
receipt settles the task even if the old native monitor no longer exists; a
pending recovery claim is not a delivered result. A later task outcome cannot authorize
the earlier completion input or settle its receipt. Cancellation, session replacement,
and missing or contradictory task identities do not authorize replay. A real held admission or a still-valid admitted input keeps recovery pending. Rejected input retains the task but releases the process monitor; it does not poll indefinitely. Native parent rotation must preserve the current connection and requester identity checks. Cold task reconstruction requires the saved native history owner. A later parent registration cannot supply missing historical ownership.
This applies to newly recorded channel-delivery claims. Route-less, transcript-only
and Control UI parents are not covered by this recovery change. Nor does it recover
every older native completion or a completion that never reached parent admission. Progress messages, empty or
truncated receipts, and uncertain sends cannot establish final delivery. The
Gateway and Codex plugin must both be updated for recovery joining. Older builds
may discard the added receipt fields while rewriting session metadata, even
without a SQL schema change. Finish pending completion recovery before downgrading;
do not delete consumed inputs or change source IDs to force another delivery.
Pending delivery rows drain or retry after restart. When a delivery exhausts its
retry budget, recovery reclaims expired producer custody. An active producer
keeps ownership. Failed deliveries cannot send again, but retain the information
needed to settle their owning session or conversation. If that update fails or
the gateway crashes, recovery resumes the update without resending the message.
After settlement, failed rows discard their payload. Only reusable or
crash-ambiguous owners keep a minimal bounded or permanent receipt that prevents
duplicate delivery. Delivery uncertainty notices retain their acknowledgment,
so a repeated settlement cannot notify the same intent again.
Finish pending settlements before downgrading. Older builds may discard their
metadata during database repair or drop acknowledged notices while rewriting
session records, even when the schema version is unchanged.
See Database schemas for downgrade precautions.
Graceful restarts drain first
Startup migration warnings do not prevent the Gateway from starting. It logs the warnings once and starts degraded.openclaw status and openclaw doctor show the
running Gateway’s warning report. Read-only operators receive the repair hint.
Warning details are restricted to administrators and startup logs.
Run openclaw doctor --fix against the same
state/config, then restart the Gateway. Unfinished migrations remain pending for
a later startup. Errors that leave required state unsafe to read still stop startup.
A requested restart (openclaw gateway restart, a config change that requires
a restart, or a gateway update) does not kill in-flight work immediately. The
gateway stops accepting new work, then waits for active agent turns and
background tasks to finish, up to a drain budget (5 minutes by default). Most
restarts therefore interrupt nothing at all.
On Linux and macOS, this also applies when startup recovers from an unsupported
Node version and the service manager tracks a launcher parent. The launcher
forwards the stop signal and waits for the serving Gateway to drain within the
shared service budget. Managed restart intent targets the live serving owner,
so unfinished work still follows restart recovery when its drain budget expires.
The launchd stop budget remains 20 seconds; Linux units use the deadlines below.
This requires a Gateway started with the updated launcher: replacing files cannot
change a launcher that is already running.
For these managed restarts, if the CLI cannot verify the service command, serving
owner, or restart-intent recording, it refuses the restart before signaling with
GATEWAY_RESTART_PREPARATION_REFUSED. Restore service inspection or state access,
verify Gateway status, and retry. An unverified launcher PID is never a fallback.
Running 2026.9.4 Gateways remain eligible through their published state-local lock
identity. The CLI verifies the service installation, live process start identity,
and membership in that native service before preparing the restart. Stale or
mismatched identities cannot authorize a running-service restart. An inactive
service can still start without restart intent once the prior owner is proven dead.
On Linux, the systemd unit must use KillMode=mixed so the initial stop signal
reaches only the Gateway. Systemd still kills remaining child processes when the
Gateway exits or its stop deadline expires. Older KillMode=control-group units
signal child runtimes immediately, which can interrupt a turn before drain finishes.
The spawn broker stays available while its Gateway connection is alive, even if
it receives the stop signal too, so cleanup can still launch commands and observe
child exits. This does not protect other child runtimes; KillMode=mixed remains
required.
Updates and openclaw doctor --fix refresh outdated OpenClaw-managed Linux unit
policy. Maintenance reads the resident shutdown budget from Gateway status.
Older Gateways without that fact follow the short-budget path: fence admission
and observe lifecycle drain until idle or the update step deadline. At the
deadline, outstanding write custody refuses the stop with its owner phase;
remaining turns can be interrupted with a recorded warning.
Operator-owned drop-ins must be inspected and updated separately because reinstalling
the base unit preserves them. See Linux services.
Maintenance custody observations
Gatewaystatus reports its process-owned shutdownBudget, with activeWork
counts and a separate writeCustody array. Suspension preparation and status
responses also include optional writeCustody entries with phase and count.
Current phases identify migration, backup, coordinator writes, session lifecycle
mutation, and terminal persistence. These are recorded by their operation owners;
ordinary root requests and cron runs do not imply write custody. Counts can overlap.
The optional field is additive. Older Gateways, including published 2026.9.5,
can omit it. Missing custody information never refuses maintenance. If the update
step deadline expires, maintenance stops with a warning that includes the latest
root-request and cron-run counts, explains the resident’s missing distinction,
and identifies the next Gateway’s refreshed stop policy. Only a reported live
write-custody phase refuses that deadline stop.
Systemd stop deadlines
At startup and when accepting shutdown, the Gateway reads its running systemd unit’s effectiveTimeoutStopUSec, including drop-ins. It logs the source and
reconciled stop budget at both points, so a repaired unit takes effect without
restarting first. Inspection and any wait for startup to finish consume the same
shutdown deadline. Active-work drain uses at most
315 seconds, with 10 seconds reserved for final chat writes and server cleanup
and another 5 seconds before systemd’s deadline. A unit with the default
90-second stop timeout therefore gets a 75-second drain and an 85-second Gateway
shutdown deadline. A shorter supervisor timeout also caps requested restart waits.
The drained work, ordering, and interruption behavior stay the same.
Service-child cleanup uses the remaining Gateway shutdown budget, leaving time
for final exit bookkeeping. A forced restart drains admitted work within the same
budget. When the restart scheduler has already exhausted its deferral budget,
cleanup retains the 10-second reserve without starting a second drain.
A restart without a supervisor handoff uses the existing shutdown
deadline for cleanup. This includes foreground Gateways inside another service’s
cgroup, restarts with OPENCLAW_NO_RESPAWN=1, and standalone updates that must
launch their own replacement. Cgroup membership alone does not provide a supervisor
that will replace the Gateway. Ordinary
cancellation keeps its five-second grace before forced termination. During
shutdown, a relay that needs forced termination after its owned processes are
confirmed gone produces a warning. Completed cleanup leaves the Gateway’s exit
status at zero; an unconfirmed process cleanup boundary still reports failure.
The process’s cgroup selects the system or user manager, independently of the
account running the Gateway or its restart owner. This also covers hand-written
system units with User=openclaw and externally managed deployments. Reading
the system unit’s timeout does not require sudo or notification support.
If the unit cannot be inspected at startup, the Gateway warns with the manager,
unit, and failure reason and uses systemd’s 90-second default as a conservative
fallback. A failed shutdown reread retains the startup budget, with elapsed time
deducted, instead of assuming a longer timeout. An explicitly unlimited timeout
keeps the normal Gateway budget. Already-running v2026.9.5 Gateways retain their
startup reading until they restart; installing newer files cannot change the
shutdown budget captured by that older process.
An already-installed old unit benefits from the clamp as soon as the new Gateway
starts, without a service rewrite. This leaves time for orderly shutdown instead
of spending the entire stop window in drain. Work that cannot settle still uses
the existing interruption and recovery path; the shorter budget cannot guarantee
that arbitrary cleanup completes. CLI installs and guided Doctor service repairs
render TimeoutStopSec=330 from the same policy as the Gateway. Doctor reports
an effective stop timeout below that requirement. Operator-owned drop-ins remain
the operator’s responsibility.
For hand-written system units, allow at least drain + 15 seconds. With the
current maximum drain, create
/etc/systemd/system/openclaw-gateway.service.d/stop-timeout.conf:
sudo systemctl daemon-reload and verify with
systemctl show openclaw-gateway.service -p TimeoutStopUSec. Restart through your
service’s deployment owner. For a user
unit, use systemctl --user edit openclaw-gateway.service and the corresponding
--user reload/show commands. Retain KillMode=mixed as described above; a longer
timeout does not protect children from KillMode=control-group’s initial signal.
Replies to pending node commands remain accepted during the drain, including
worker cleanup started by shutdown. Each reply must still match its live
invocation, node connection, pairing generation, and owning lifecycle. This
lets cleanup finish without waiting for a command timeout. It does not reopen
admission for new requests.
Only work that cannot finish inside the drain budget (or any run interrupted
by a forced restart or a crash) is aborted — and before that happens, each
affected session is marked for recovery.
Restart cancellation also preserves recoverability when the bulk shutdown marker
cannot be written. Native runtime preparation interrupted by the same Gateway
restart is recorded as restart cancellation rather than a provider failure.
Explicit user cancellation and genuine execution timeouts
remain terminal. Recovery startup uses the admitted run’s existing deadline,
including runtime preparation and waiting for session or global capacity. Waiting
in a healthy queue does not consume separate failed-start attempts.
sessions.abort waits for the cancellation’s session write before acknowledging
success. Restarting immediately after that acknowledgment preserves the terminal
outcome even if the run’s finalizer has not finished.
This also applies to a parent that yielded while waiting for spawned tasks:
successfully stopping its children records the captured parent’s cancellation
before acknowledging, without overwriting a newer turn in that session.
If another child cannot be stopped, the response still reports incomplete
cancellation; the captured parent’s cancellation is persisted before that error.
Host sleep and process freezes
When a gateway host wakes from sleep, a virtual machine resumes, or the process continues after a long pause, the gateway detects the freeze within about 30 seconds. It restarts channel connections once tracked Gateway work is idle, then refreshes cached health and presence. The health and presence refresh still runs when a busy gateway defers only the channel restart. This keeps stale sockets from waiting for their normal expiry without interrupting an active reply or agent startup when a busy event loop caused the timer gap. The macOS app and Linux companion cooperate with a local gateway by preparing a short suspension lease before the host sleeps and resuming it after wake. Remote gateways are not suspended when the app host sleeps. A deliberate suspension throughgateway.suspend.* keeps recovery deferred until the controller resumes
the gateway.
Recovery after a failed update
After a failed interactive update or repair, OpenClaw finishes cleanup and any service recovery, then opensopenclaw triage. Triage immediately
starts the first directly launchable coding agent in this order: Claude Code,
Codex, OpenCode, then Pi. It passes the captured failure before fresh Doctor
checks or archive collection and asks the agent to diagnose, repair, and verify
the installation. The agent receives the captured installation paths and keeps
its normal authentication, sandbox, and approval settings.
For a failed Control UI or unattended update, use the installation-specific
command printed on the Gateway host, or run triage there with the same OpenClaw
profile and state/config paths. Use --agent to select a particular coding agent:
--yes, and non-interactive update invocations collect diagnostics without
starting an external coding agent. openclaw triage --non-interactive also prepares
diagnostics without launching an agent. --update-result <path> includes an
updater’s saved failure artifact. Printed handoff commands preserve installation
selectors and use PowerShell on Windows or POSIX shells on macOS, Linux, and WSL.
Staging and validation run while the old Gateway serves. The candidate runs
Doctor lint, config and plugin planning, and an isolated canary boot against
copied configuration and verified database snapshots. Migrations on these
copies rehearse the upgrade without changing live state. A validation failure
can enter bounded unattended repair
while the old Gateway keeps serving. Activation requires the failed check to
pass. Otherwise the candidate is discarded. An already-current no-op never
stops the Gateway.
Older targets that predate migration continuation record runtime validation as
unavailable and use the existing downgrade finalization path.
The detached helper also waits for the activating phase before parking its
parent Gateway. The first activation window contains the swap, required live
migrations, and service start. Plugin package download and sync run while the
core Gateway serves. A changed plugin snapshot requires a second measured
activation window: full Doctor migrations under exclusive maintenance, then
restart and verification. Unchanged plugins do not run another full Doctor pass.
After activation, the updater verifies that the managed service is running and
owns its port, the Gateway hello handshake matches the expected version/build
identity, a 12-probe health settle passes, plugins and channels are healthy, and
/readyz returns HTTP 200. Update verification does not use model inference.
Startup receives the update’s existing per-step --timeout budget (1800 seconds
by default), including migration and listener initialization, followed by the
12-probe settle window. On the first update from an older release, the old updater
invokes the newly installed CLI but does not pass that readiness budget. The
candidate recognizes the existing update marker and, once the managed process is
running, uses the five-minute startup watchdog instead of the standalone
60-second deadline. Migration, listener, and health transitions do not reset this
bound. The old updater’s subprocess timeout also remains in force. An exhausted
wait reports the last observed startup phase. Standalone restarts use the progress-gated readiness wait.
Verification facts and measured downtime are retained in the
update run report.
When a package fails verification, the updater compares the shared and affected
per-agent SQLite user_version values and configuration content with their
pre-activation values. If they are unchanged and the previous runtime was
verified before activation, it restores the previous package, command shim,
service definition, and config writer stamp, then starts that runtime and repeats
the CLI verification checks. Successful recovery leaves that Gateway running
and finishes rolled-back, with the failing check kept as the reason and
downtime covering service stop through verified recovery. The writer-stamp guard
does not block this intentional recovery. Its allowance is scoped to rollback
service commands and never persisted. See
Automatic rollback.
If configuration content or a schema version changed, automatic rollback is
refused (state-migrated-no-rollback) and the updater attempts bounded repair on
the installed candidate. The same repair slot can run when rollback itself fails.
Code rollback cannot reverse state migrations. An unavailable schema comparison also prevents
automatic rollback (rollback-state-unverified). After migration,
a fresh candidate process finishes verification and the same durable run report.
The old updater does not reopen the newer database. Git activation failures before live migrations can restore
the previous source and retained built runtime. Later Git failures retain the
candidate for diagnosis.
An update failure does not by itself authorize a candidate restart. Candidate
activation still requires successful validation. A blocking live Doctor result
does not become a restart grant. The previous runtime was verified before the
update, so rollback across unchanged configuration and schemas may restart it
under that prior verification and must verify it again afterward. A detached
helper or Windows task autostart cannot bypass this decision.
During post-activation repair, the orchestrator starts or restarts a stopped or
unhealthy service once after each turn, then reruns verification. Passing checks
allow the run to succeed. If rollback already restored the previous release,
successful repair finishes rolled-back and the command still exits nonzero.
Otherwise it fails with the original reason and repair summaries. The agent
cannot issue service lifecycle commands.
On Windows, captured Scheduled Task autostart stays suspended through Doctor
finalization. The updater enables the task for activation and restores
suspension if final verification fails, including after a migrated-state handoff.
Native task-control failures appear in the update report. Failed suspension
never triggers automatic re-enablement of the rejected installation.
On macOS, a terminated update helper can leave the selected Gateway LaunchAgent
installed but unloaded and disabled across logins. openclaw doctor and
openclaw doctor --fix diagnose this state. --fix leaves an already-stopped
Gateway stopped. If the update was interrupted or installation safety is
uncertain, rerun openclaw update or use Doctor and triage before starting it.
Once verified, run openclaw gateway start (or
openclaw --profile <profile> gateway start) to re-enable and start that service.
Keep the same state/config and custom-label overrides. Doctor prints the selected
label and recovery command. Interactive Doctor can offer bootstrap repair.
A cancellation before package mutation can restore the original service under
its existing handoff ownership. Recovery succeeds only after the Gateway passes
the normal restart health checks and reports the verified installation version
and, for Git recovery, the exact restored build ID. A matching package version
alone cannot distinguish two Git builds. A service
manager accepting a start request, or reporting a live PID, is insufficient.
Once the detached helper launches the updater, a missing, malformed, oversized,
or interrupted direct result leaves activation to the operator. This is stricter
than older helpers that restarted after an unclassified failure. Installing a new
target does not change an already-running historical helper. These checks apply
to the helper version that started the update.
A skipped update before activation does not park or restart the Gateway. If an
interruption occurs after parking, the helper uses the child’s verified recovery
decision and preserves the original reason. A zero exit is retained only if
required recovery succeeds or the child already verified it.
Updater exit code 79 keeps the Gateway parked only when the previous generation
cannot be safely restored and verified. When the updater has restored the previous
generation across unchanged configuration and schemas and supplies a verified
recovery decision, the helper starts and verifies it instead of leaving it
stopped. Helper recovery verifies service liveness, version/build identity,
plugin activation, and channel health. It does not repeat the separate /readyz
probe. That report field remains unverified.
The run then finishes rolled-back with the previous version and measured
downtime. Missing recovery proof, migrated state, or failed restoration still
requires repair before restart. A service that is observed stopped is recorded
as stopped. The report does not reuse its pre-activation running status.
A terminal failed update still exits nonzero when later service recovery or
triage repair succeeds. Error and skip notifications are attempted before recovery. The helper
does not recreate them after the recovering Gateway consumes them. Check the
final CLI result and the handoff log for the recovery outcome.
Repair the failed Doctor or installation check before restarting. Triage can
inspect openclaw gateway status --deep and the update diagnostics. Avoid blindly installing
older code after a newer release has migrated configuration or databases. See
Updating and recovery. Restart sentinels report the outcome.
Copying one does not grant permission to restart a service.
How interrupted work is detected
Startup reconciles older subagent session rows that still sayrunning but have
no live run, task, admission, or recovery owner. It records a diagnostic transcript
receipt and marks the row interrupted in one transaction. The end timestamp records when
startup observed the interruption, rather than an inferred execution finish time;
the original activity timestamps remain intact. A failed receipt write becomes a
warning and leaves the row eligible for a later repair.
Three complementary mechanisms mark sessions whose turn did not finish:
- At turn admission: for an ordinary text turn on an existing main session,
the gateway appends the user message, marks the session running, and records
its recovery delivery claim in one SQLite transaction before model or
before_agent_replyhook execution. Control UI does this before returning thestartedacknowledgement. Channel dispatch does it when the prepared turn adopts the agent run. Commands, attachments, per-turn overrides, pending deliveries, prior abort hints, plugin-owned sessions, and turns with execution hooks keep their specialized admission paths. If abefore_agent_replyhook is installed, admission records enough phase state to distinguish a completed silent result from an ambiguous side-effect window. Recovery dispatches an ordinary user-triggered agent turn, so the currently loadedbefore_agent_replyhooks run under their normal trigger rules. Ambiguous prior hook outcomes resume with restart-safe tools rather than replaying unrestricted side effects. - At shutdown: during the restart drain, every session with an active run is stamped with a recovery marker in the session store before the run is aborted.
- At startup: the gateway scans session stores for sessions that still claim to be running but have no live owner in the new process. This catches hard crashes and kills where no shutdown code ran. Stale transcript lock files are cleaned up at the same time.
openclaw status and openclaw doctor show
outstanding startup recovery failures from the running Gateway; the warning clears
when the store scan succeeds.
If an older Gateway left a dead writer and an unfinished recovery cycle in a
running, failed, or statusless session, sessions.recover reconciles that writer
and starts a continuation in the same session. A new Control UI message also reconciles this
state before admission, so a rejected send cannot trap the conversation in a
“conversation changed” retry loop. Both paths preserve the session key and
transcript. A live run or cloud worker still prevents this repair. Tombstoned
sessions retain their separate recovery path into a new session.
Automatic resume
A few seconds after startup, the gateway re-dispatches each marked session with a synthetic system message telling the agent its previous turn was interrupted by a restart and to continue from the existing transcript. If a final reply had already been produced but not delivered, its text is included so the agent can deliver it instead of redoing the work. The restart does not cancel the user’s task. The agent checks the current state, reconciles tool results whose outcomes are unknown, and continues without asking the user to repeat the request. Preparing a new message cannot consume the interruption marker; the recovery owner retains it until work is adopted or settled. When a recovered turn starts with an eligible channel delivery route, OpenClaw sends a resumption notice to that conversation, retaining its account and topic. The final reply uses the same delivery route. Transcript-only turns stay private, and a turn that has already finished does not receive a late resumption notice. A failed notice does not restart or replay the recovered work. Main-session resumption notices are best-effort and live-only: automatic-delivery permission and the recovery owner are rechecked immediately before the channel send. They are not replayed from the outbound queue; terminal-failure notice retries and normal final-reply delivery are unchanged. Telegram renews its typing indicator while the recovered turn runs. Typing stops when the turn settles, its recovery owner changes, or the gateway closes, and respectstypingMode: "never". Other channels can opt in through the guarded
typing hook; unsupported channels still receive the resumption notice.
Channel plugins opt in with heartbeat.sendTypingGuarded(...). Alongside the
recovery delivery target, core supplies an AbortSignal and an
assertPlatformSendAuthorized callback. Plugins must honor cancellation through
queued sends and invoke the callback immediately before the platform request,
after asynchronous preparation. Recovery does not fall back to the unguarded
heartbeat.sendTyping(...) hook.
Startup reconciliation retries transient failures up to three times with
exponential backoff. Separately, each interrupted main-session cycle has a
durable budget of three charged automatic dispatch attempts, retained across
gateway restarts. OpenClaw charges an attempt before dispatch, refunds it when
the gateway explicitly rejects the request before acceptance, and retains the
charge when a post-dispatch result is uncertain to avoid replaying work.
Foreground work that already owns the session keeps automatic recovery out
until that work settles.
After the durable budget is exhausted, the session is tombstoned instead of
looping forever. Inspect the failed session and use /new or /reset to start a
replacement. openclaw doctor --fix can repair a stale aborted flag that
conflicts with a tombstone, but it does not re-enable that recovery cycle.
If you message the failed session again in a channel, OpenClaw sends a short
recovery reminder through that channel and logs each rejected message at warn
level with the session key, recovery reason, and recovery command. Repeated
reminders are suppressed in a bounded memory cache. Resetting or deleting the
session, or restarting the Gateway, clears that suppression. Sessions with locked
model selection instead direct you to Resume in new session in WebChat.
Every retry reuses one durable dispatch identifier, so an ambiguous connection
failure cannot start the same recovery twice. Completed Control UI turns also
retain bounded durable idempotency tombstones, allowing a reconnecting outbox
to retire them without re-executing the request.
Message-tool-only replies use a second durable correlation. Before a terminal
same-conversation send reaches the channel, the gateway records an unresolved
delivery intent on the exact session and source turn. A confirmed provider
success resolves it to a durable delivered receipt. A confirmed failure clears
it. Recovery completes a delivered receipt without rerunning tools. If a crash
leaves the provider outcome unknown, recovery resumes with restart-safe tools
so the model can inspect and report the ambiguity without replaying the
external effect.
The delivered reply is also mirrored into the transcript with its source
message ID. Terminal mirrors use a distinct receipt key, so a progress send with
the same provider idempotency key cannot mask the terminal marker. Progress
sends and receipts from older turns cannot complete the current turn. Only
durable channel-ingress claims can restore message-action authority. A resumed
run keeps the original source-delivery mode and source correlation, including
requester identity and any same-channel/thread restriction, so the same receipt
remains authoritative even if another restart happens during recovery. A
message-tool-only turn without reconstructable channel authority is tombstoned
because OpenClaw cannot safely mint message-action authority without the
original channel-ingress claim. The terminal notice directs the user to start a
replacement with /new or /reset.
A recovered Control UI turn can finish pinned dashboard widgets
using the interrupted turn’s exact session and recovery claim. A browser connection
does not survive the restart: recovery retains dashboard authoring, while inline
and device presentation still require their normal client capabilities.
Before resuming, the gateway classifies the transcript tail to choose the tool
restriction for the continuation. An aborted turn is the interruption itself,
so it resumes on a best-effort basis whatever abort detail the provider or worker recorded with it:
partial streamed text stays in the transcript and the continuation picks up from
the message beneath it, while a tool call left dangling is dropped from the next
provider payload. Provider failures, completed assistant tails, empty transcripts,
and stale pending approvals also continue from the existing transcript. States
with ambiguous side effects normally use restart-safe tools. A session with
effective Full Access, including an inherited Full Access default, keeps its
ordinary tools so it can inspect the outcome and finish the task. Recovery does
not replay the interrupted call automatically or treat its missing result as
success. Existing tool restrictions and current permissions still apply.
Pending reply delivery, ambiguous reply-hook outcomes, and explicitly replay-safe
Code Mode reconstruction retain their narrower recovery restrictions.
OpenClaw can also reconstruct interrupted read-only Code Mode
work. Code Mode marks these runs as restart-safe and rejects side-effecting
catalog or namespace tool calls before they execute. If a restart lands on
the wait control, the new gateway reconstructs the turn from its transcript
and forces the reconstructed execution to remain restart-safe even if the
model omits or clears that flag. The host filters the entire reconstructed
turn to audited read-only core tools and explicitly replay-safe plugin tools,
including when Code Mode is disabled after the restart. Other interrupted
Code Mode work resumes for model reconciliation: Full Access keeps its configured
tool surface unless the current turn has an explicitly replay-safe checkpoint.
Other sessions retain the restart-safe restriction. Old process-local runs and
approval handles are not revived.
Subagents
Subagent runs are persisted in the shared SQLite state database, so the subagent registry survives the process. On boot, interrupted child runs settle through their normal completion path. They are not automatically relaunched. The parent receives the interruption outcome and owns finishing the user’s task. It can inspect retained child history, continue that child withsessions_send,
or spawn a replacement after checking that the old execution has stopped.
Existing cleanup and retention settings still apply.
If a parent yielded while waiting for children, its saved batch collects both
completed and interrupted results and wakes the parent once the batch settles.
A parent already working on those results resumes through ordinary main-session
recovery. A child result or an announce: run identifier does not make unfinished
parent work disposable. The recovery turn explains the restart and tells the
parent to check current state and uncertain effects before continuing.
A completed child may still owe its requester a final follow-up. If that
follow-up is waiting to retry or is interrupted by restart, the saved
obligation survives and resumes after startup. Restart admission rejection
does not consume an attempt, and cancellation of an admitted attempt does
not exhaust the obligation. Existing delivery retry limits still apply.
Settling a yielded turn’s wake leaves its unfinished task and final delivery
intact. A completed cancellation can also finish wake bookkeeping after its
task record expires, without recreating the task or repeating cleanup.
Recovery reconciles an expired cancellation’s retained marker before retrying
its requester wake, preserving the original cleanup record. Live child cancellation
can wake a waiting requester while normal cleanup reconciliation completes.
A delayed cancellation callback cannot reopen completed cleanup.
Background tasks
The background task registry is SQLite-backed and reconciled on boot and on a periodic interval: durable outcomes recorded by finished runs are recovered, and runs whose owning process disappeared are marked lost after a grace period instead of hanging forever.Agent-requested restarts
When the agent itself triggers a restart (applying a config change, updating the gateway, or an explicit restart request), a restart sentinel is written to SQLite before the process exits. After boot the gateway posts the outcome back to the originating chat and dispatches any requested one-shot continuation turn so the agent picks up exactly where it left off, on the same channel and thread. For updates, the sentinel carriesstats.runId, linking the detached updater to
its durable update_runs record. The new Gateway records its observed running
version, build, and startup facts there. It preserves a terminal outcome already
written by the updater and waits while a managed handoff is still pending.
Before preparing notices or continuations, it reconciles a newer final sentinel
for that same run and handoff. A pending sentinel keeps its existing bounded
retry window even when the ledger is already terminal; an unrelated replacement
remains untouched. If the helper never publishes its final sentinel, expiry
reports the recorded terminal outcome without changing it. A still-running
Gateway-owned row finishes as failed with restart-unhealthy; CLI-owned runs
retain their updater’s authority and outcome.
The post-restart notice is rendered from that row using the same report as
openclaw update status. Consuming the sentinel does not remove run history.
Sentinels left by older releases retain their existing delivery route.
Any update run with an existing internal origin session, including Control UI
and webchat, appends its report directly to that session’s transcript, even when
the caller supplied only sessionKey and no deliveryContext. A completed
update with no continuation does not wake the model to deliver the report.
The sentinel’s typed SQLite columns are authoritative for restart handling.
Its payload_json value is a replay/debug shadow only. Runtime reads, writes,
and clears SQLite state without a file fallback. A bounded state migration runs
at startup and through Doctor to preserve a validated legacy
restart-sentinel.json left on disk after an update.
The migration verifies the typed row and removes the source file before normal
restart handling continues.
Safety valves and observability
-
Crash-loop breaker: 3 unclean boots within 5 minutes trip a breaker that
suppresses auto-start side services on the next boot, so a crashing gateway
does not amplify itself. A continuously stable safe-mode gateway rechecks the
breaker after the full unclean-boot window drains and then resumes deferred
channel auto-start without requiring another gateway restart.
When the breaker is tripped, the control plane still starts, but channel
plugins (and other auto-started side services) stay down until an operator
manually overrides the suppression or the full window drains with no unclean
boots. Recovery preserves channels that an operator manually stopped and any
separate development-mode suppression. Gateway logs look like:
channel autostart suppressed by crash-loop breaker; refusing automatic start for <channel>… Start a channel manually with: openclaw gateway call channels.start --params '{"channel":"<id>"}'Operator recovery SOP:-
Confirm the gateway process is up (
openclaw gateway status/ LaunchAgent or systemd unit still running). A “channel disconnected” symptom often means suppressed autostart, not a dead gateway. -
Inspect channel state:
openclaw channels status(add--probewhen useful). Look for stopped / not connected accounts while the gateway itself is healthy. - Fix the root cause of the unclean boots (bad config, plugin crash on start, missing secrets) before forcing channels back up.
-
Manually start a channel while suppression is active:
channels.startis a manual override. It does not disable the breaker for other channels. -
Or leave the healthy gateway running until the full unclean-boot window
drains. The same process logs that the restart-loop breaker recovered and
starts the deferred configured channels.
If that message does not appear after the window plus one health-monitor
interval, inspect the gateway logs and run
openclaw doctorbefore restarting.
-
Confirm the gateway process is up (
- Main-session attempt budget: three charged automatic dispatch attempts per interrupted cycle. Exhaustion tombstones that session until it is inspected and replaced.
-
Metrics: recovery activity is exported via
Prometheus as
openclaw_session_recovery_totalandopenclaw_session_recovery_age_seconds. -
Logs: recovery decisions are logged under the
main-session-restart-recoveryandagents/subagent-registrysubsystems. -
Reply hooks: resumed turns run currently loaded
before_agent_replyhooks under the normal user-trigger rules. Automatically delivered replies also run the normalreply_payload_sendinghook before channel delivery, with the recovered session, run, account, and conversation context.
Verify recovery after an update
A healthy Gateway confirms availability, not completion of interrupted work. Check each previously active session and its child tasks: it should have finished before shutdown, resumed execution, or reached a visible terminal outcome or recovery error. Check queued inputs separately for transcript consumption or an explicit unresolved state. The main-session recovery log distinguishes execution resumption from the latermain-session restart recovery terminal event. A recovered count at startup means
execution resumed. It does not prove that an assistant reply was delivered.
Use the session transcript and recorded delivery outcome to verify completion.
What is not resumed
- Sessions excluded from main-session recovery because another owner already handles them: subagent sessions (settled back to their parent), cron sessions (the scheduler re-runs on schedule), and ACP-managed sessions (the connected IDE or client owns the resume).
- Work that was never admitted: messages arriving during the drain window are rejected with an explicit restart error rather than silently queued into a dying process.
- Gateway terminal PTYs, including operator- and agent-owned terminals. They are process-local and end when the Gateway restarts.
- Standalone embedded turns cannot take over a main session with pending
restart recovery because they do not share the gateway’s lifecycle owner.
Run the turn through the gateway or reset it there with