Skip to main content
What the wire looks like before any method call: the published packages, the frame shapes, the payload limits, and the Gateway-controlled WebRTC Talk contract.

npm packages

Follow Install the packages for the verified stable release, exact-version commands, and compatibility guidance. Package release versions are separate from the wire protocol version and the root openclaw CLI release.
  • @openclaw/gateway-protocol publishes the schemas, validators, TypeScript types, lightweight frame and error helpers, and version constants. Its tarball includes the generated protocol.schema.json machine-readable contract as a downloadable file, not an exported import subpath.
  • @openclaw/gateway-client publishes the reference Node client and a browser-safe entry at @openclaw/gateway-client/browser.
For application lifecycle guidance, see Building a Gateway client. For apps that supervise the Gateway as a child process, see Embedding OpenClaw.

Transport and framing

  • WebSocket, text frames, JSON payloads.
  • First frame must be a connect request.
  • Pre-connect frames are capped at 64 KiB (MAX_PREAUTH_PAYLOAD_BYTES). After handshake, follow hello-ok.policy.maxPayload and hello-ok.policy.maxBufferedBytes. With diagnostics enabled, oversized inbound frames and slow outbound buffers emit payload.large events before the gateway closes or drops the frame. These events carry surface, byte sizes, limits, and a safe reason code, never message bodies, attachment contents, raw frame bytes, tokens, cookies, or secrets.
  • The Gateway does not negotiate permessage-deflate. Browsers can compress even tiny requests when the extension is enabled; serial decompression then delays each request behind busy event-loop turns before handler scheduling. Uncompressed frames preserve responsive request bursts at the cost of more bandwidth for large histories and rosters. Payload limits are unchanged.
Frame shapes:
  • Request: {type:"req", id, method, params, traceparent?, expectedProfileId?}
  • Response: {type:"res", id, ok, payload|error}
  • Event: {type:"event", event, payload, seq?, stateVersion?, recipientProfileId?}
After authentication, a client may include a W3C traceparent string on each request frame. The Gateway continues a valid value as a child trace context for that request. Missing or syntactically malformed values within the 128-character field limit keep the default fresh request trace and do not fail the RPC; longer values make the request frame invalid. The initial connect request never establishes trace context for later frames. Use a separate traceparent for each logical request on a long-lived connection; do not treat the WebSocket itself as one trace. Response errors use { code, message, details?, retryable?, retryAfterMs? }. Authenticated operator requests share a bounded queue for starting RPC handlers. When waiting capacity is exhausted, the Gateway returns retryable UNAVAILABLE before the method runs; retry within the request’s budget. Started requests complete concurrently, so responses can arrive out of order. Ordinary UI/SDK requests may outlive a socket disconnect, but cannot start a handler in a retiring Gateway instance. Shutdown fences new request entry and joins pending handler loading and authorization before releasing their runtime. Already-started methods retain their own shutdown behavior; shutdown does not wait for every RPC to finish. Exact pending node progress and result replies remain available during node cleanup, until transport shutdown seals entry. Clients should branch on code and details.code; message remains human-readable and can change except where a compatibility note says otherwise. Method-level authorization failures use top-level code: "FORBIDDEN" with structured missing-scope details:
  • Missing scope: { code: "MISSING_SCOPE", missingScope, requiredScopes }. requiredScopes is the complete known scope set for the requested operation. The legacy missing scope: <scope> message is retained for older clients.
Clients should read details first and use the legacy message only as a compatibility fallback. readMissingScopeError and readMissingScopeErrorDetails are exported from @openclaw/gateway-protocol/gateway-error-details; the browser-safe gateway client re-exports them from @openclaw/gateway-client/browser. The schemas are exported as GatewayErrorDetailsSchema, MissingScopeErrorDetailsSchema from @openclaw/gateway-protocol/schema. HTTP scope failures mirror the MISSING_SCOPE object under error.details and use HTTP status 403. Side-effecting methods require idempotency keys (see schema).

Profile binding

Use profile binding only when hello-ok.features.capabilities includes profile-binding-v1. A client that requires this contract must report it as unavailable when the capability is absent, rather than silently sending an unbound action. Requests that omit expectedProfileId retain existing behavior. expectedProfileId is an optional opaque string of 1 to 128 characters on an authenticated request frame. The Gateway compares it exactly with the current canonical profile ID of the authenticated principal. It does not trim, fold case, or follow merge aliases on the expected value. Obtain the ID from users.self; a Gateway URL, account label, agent ID, or session key is not a profile ID. A missing authenticated profile cannot satisfy the precondition. A server advertising the capability checks the precondition at RPC entry and before returning a response payload. Commit-time revalidation is method-specific; the capability does not promise atomicity inside arbitrary methods or plugins. An entry check followed by asynchronous work is not itself a commit guarantee. The structured error sets error.details.reason to EXPECTED_PROFILE_MISMATCH and carries a per-attempt classification in error.details.execution:
  • not_started: no execution was started by this attempt.
  • may_have_executed: the method may have run before the mismatch was detected; the error is not evidence of rollback.
Neither classification clears uncertainty from an earlier attempt or overrides a known acknowledgment (ACK). Preserve the original idempotency key and reconcile the earlier outcome before retrying uncertain work. Ordinary socket disconnects do not cancel already-accepted work. On authenticated operator broadcasts, optional recipientProfileId identifies the recipient’s canonical profile at publication. It is a per-recipient frame fact, not the event’s origin, a run-owner identity, or an authorization grant. Existing event permissions and subscriptions still govern delivery. Bind the consumer to both its physical Gateway connection and selected profile; if the recipient field is missing or differs, stop applying the event to that bound view or action and surface the binding failure. This contract does not cover pre-authentication events, node event delivery, APNs notifications, or in-process publications. It does not revoke provider-direct media or already-issued WebRTC credentials, and it does not promise immediate revocation of retained sessions.

Connection keepalives

Authenticated control connections use WebSocket ping/pong keepalives. These are separate from scheduled agent heartbeats; disabling agent heartbeats does not disable connection monitoring. A ping queued behind outgoing data is governed by transport inactivity, including partial write progress and incoming traffic. Once its write completes, the peer gets a full 25-second pong window; unrelated incoming messages do not extend that window. The periodic check closes expired connections and releases their owners. Transport inactivity is not an independent write-only deadline: a peer sending traffic can keep a queued write alive. Existing slow-consumer buffer limits still apply. Streaming transports retain their stream-owner lifecycle policy.

Gateway-controlled WebRTC Talk

talk.client.create accepts the additive capability gateway-control-v1. The released browser/Gateway-owned WebRTC route tries OAuth first and falls back to Platform API-key authentication. Direct backend sockets and unlisted or private realtime routes require Platform API-key authentication. A successful result includes clientControl: { owner: "gateway" }, a 60-second single-use Gateway broker token in clientSecret, and the relative offerUrl: "/plugins/openai/realtime/calls". The client sends only application/sdp to that route with the broker token. It must not create a provider control data channel. The Gateway creates the call, attaches the provider sideband before returning the answer SDP, and owns tool, transcript, steering, cancellation, and close lifecycle. Clients that omit the capability retain the existing browser session behavior. A Gateway or configured authentication path that cannot provide the requested owner returns UNAVAILABLE; it never downgrades the request to client-owned control. Clients must close their local media peer if the Gateway connection is lost or a talk.event for their current voiceSessionId contains talkEvent.type: "session.closed". Ignore terminal events for other calls; a recoverable session.error alone is not a close notification.